Hydrostatic Test - A test of sprinkler piping which subjects all piping and devices to a static pressure of at least two hundred (200) pounds per square inch for a period of not less than two (2) hours. In the event that the static pressure is in excess of one hundred-fifty (150) pounds per square inch, the test pressure shall be a pressure of at least fifty (50) pounds per square inch greater than the static pressure. This unit also contains the necessary equipment for transmitting alarms to the Fire Department. The system is usually activated by heat from a fire and discharges water over a fire area.įire Alarm Control Panel (FACP) - A UL-listed, FM-approved control unit which will receive signals from remote detection and signaling devices, sound an audible and visual evacuation alarm and signal the Fire Department through a direct connection. Each sprinkler system riser includes a control valve and a device for actuating an alarm when the system is in operation. The portion of the sprinkler system above ground is a network of specially sized or hydraulically calculated piping installed in a building, structure or area, generally overhead, and to which sprinklers are attached in a systematic pattern. This installation includes one (1) or more automatic water supplies. 11-08.Ī. For the purpose of this chapter, the following terms, phrases, words and their derivations shall have the meanings given herein. The word "shall" is always mandatory and not discretionary.Īnnunciator - A unit containing two (2) or more identified targets or indicator lamps in which each target or lamp indicates the circuit condition or location to be annunciated.Īuthority Having Jurisdiction - The Chief of the Northborough Fire Department.Īutomatic Sprinkler - A device which automatically distributes water upon a fire in sufficient quantity either to extinguish it entirely or to prevent its spread.Īotomatic Sprinkler System - An integrated system of underground and overhead piping designed in accordance with fire protection engineering standards.

fire sprinkler system design shall be per nfpa 13d

2-16.įire and Ambulance Departments – See Ch. 2-09-020 New Nonresidential Fire Sprinkler SystemsĢ-09-030 New Motels, Hotels and Rooming HousesĢ-09-040 Residential Units Containing Four or More DwellingsĢ-09-060 Dry Chemical, Carbon Dioxide and Fixed Water Spray Systemsīuilding and fire prevention – See Ch.








Fire sprinkler system design shall be per nfpa 13d